Recipe Setup
9–16
Recipe Setup
Screens
Information
S5:
Setup Flow Control
SETUP
Recipe: 1
Station: 1
FLOW CONTROL
Enter the Purge Override Setpoint:
> 000 %
Enter the Fill Override Setpoint:
> 000 %
Enter the Gun 1 Gain Factor (1-1000):
> 000
Enter the Gun 1 Flow Setpoint:
> 000 cc/min
Type the desired number entry for each field.
Press
after each entry.
Next screen
.
Purge Override Setpoint
Sets the percentage to open the fluid regulator during
a purge cycle. Generally use a setting of 100% to allow
maximum fluid flow.
Fill Override Setpoint
Sets the percentage to open the fluid regulator during
a fill cycle. Generally use a setting of 100% to allow
maximum fluid flow.
Gain Factor
The gain factor setting affects the rate at which the
system will adjust to a change in flow rate. Start with a
setting of 500 and adjust as needed. See page 9–17
for graphic examples of three different settings.
Flow Setpoint
The flow setpoint should be set according to the recipe
requirements. The setpoint for the recipe is loaded
when a recipe change is made.
The flow rate setpoint can be overridden by the
operator on a Run Monitor screen or by an
analog input.
Robotic Users:
The flow control system was
designed to maintain consistent flow rates in a
changing environment. However, it does not
jump from one setpoint to another without small
reaction time delays. If a part is being painted
that requires changes of coating thickness in
specific areas, increasing or decreasing the
robot arm speed through these areas will
provide better results than manipulating flow
control settings.
Summary of Contents for PrecisionMix ii
Page 6: ...6 ...
Page 7: ...1 1 Warnings Warnings 1 ...
Page 8: ...1 2 Warnings ...
Page 11: ...Overview 2 1 Overview 2 ...
Page 12: ...2 2 Overview ...
Page 15: ...Overview 2 5 ...
Page 31: ...Installation 3 1 Installation 3 ...
Page 32: ...Installation 3 2 ...
Page 58: ...Installation 3 28 Notes ...
Page 67: ...Operation 4 1 Operation 4 ...
Page 68: ...Operation 4 2 ...
Page 83: ...Operation 4 17 Notes ...
Page 90: ...Operation 4 24 ...
Page 91: ...Screen Map 5 1 Screen Map 5 ...
Page 92: ...5 2 Screen Map ...
Page 94: ...5 4 Screen Map ...
Page 95: ...Run Monitor 6 1 Run Monitor 6 ...
Page 96: ...Run Monitor 6 2 ...
Page 103: ...Totalizers 7 1 Totalizers 7 ...
Page 104: ...Totalizers 7 2 ...
Page 108: ...Totalizers 7 6 ...
Page 109: ...System Configuration 8 1 System Configuration 8 ...
Page 110: ...System Configuration 8 2 ...
Page 142: ...System Configuration 8 34 ...
Page 143: ...Recipe Setup 9 1 Recipe Setup 9 ...
Page 144: ...Recipe Setup 9 2 ...
Page 165: ...10 1 Troubleshooting Troubleshooting 10 ...
Page 166: ...10 2 Troubleshooting ...
Page 182: ...10 18 Troubleshooting ...
Page 183: ...11 1 Service Service 11 ...
Page 184: ...11 2 Service ...
Page 192: ...11 10 Service ...
Page 193: ...12 1 Parts Parts 12 ...
Page 194: ...12 2 Parts ...
Page 207: ...12 15 Parts Notes ...
Page 228: ...12 36 Parts ...
Page 229: ...13 1 Utilities Software Utilities Software 13 ...
Page 230: ...13 2 Utilities Software ...
Page 254: ...13 26 Utilities Software ...
Page 255: ...14 1 Technical Data Technical Data 14 ...
Page 256: ...14 2 Technical Data ...
Page 259: ...14 5 Technical Data Notes ...