System Configuration
8–8
System Configuration
Screens
Information
C7:
Solvent Meter
SYSTEM CONFIGURATION
Station: 1
SOLVENT METER
Select Solvent Meter to be:
1. Off
2. On
> 1
Type the number to turn the solvent meter on
or off, then
. Next screen
.
You can turn the input to the solvent meter off or on.
Select #1 if a solvent meter is not installed in the
system. Select #2 if a solvent meter is installed in the
system.
The solvent meter will be disabled if both the
Flow Control and Gun 2 options are selected.
If #1 is selected, a purge must be done by time.
Purge method is set with the Purge Sequence
screen (C8A). Solvent meter information will not
appear on totalizer screens, run monitor screens,
and purge and color change screens.
If #2 is selected, a solvent meter must be installed
in the system. This selection will cause solvent
meter information to appear in the totalizer screens,
run monitor screens, and purge and color change
screens, where applicable. Purge by volume is
enabled.
C8A:
Purge Sequence: Valves
SYSTEM CONFIGURATION
Station: 1
PURGEĄSEQUENCE:VALVES
Select Total Number of Purge Valves:
1. 1 Purge Valve
2. 2 Purge Valves
3. 3 Purge Valves
> 3
Select the Purge Method
1. Purge Based on Time
2. Purge Based on Volume.
-PRESS NEXT FOR MORE PURGE PARAMETERS-
Type the number for the total number of purge
valves in your systems, then
.
Type the number for the desired purge
method, as applicable for your system,
then
. Next screen
.
Set the total number of purge valves and the purge
method.
Total Number of Purge Valves
Select #1, 1 Purge Valve, if you want solvent purge
alone and have only one purge valve.
Select #2 if you want alternating solvent and air
purge and have two purge valves. This is the
default selection as it is most commonly used for
purging.
Select #3 if you want the inside of the second
integrator to be flushed. Recommended when the
system is set up with catalyst (Component B)
dispensing into the second integrator.
Purge Method
The purge method portion will only appear if the
solvent meter was turned on in the Solvent Meter
screen (previous) and
No Color Change"
is
selected when configuring screen C14 – Integrated
Color Change (page 8–12). Time is the only pos-
sible purge method when Integrated Color Change
is activated.
Purge Valves A and C can only be purged by time
as they are used for air and solvent.
Purge Valve B can be purged by either time or
volume.
Summary of Contents for PrecisionMix ii
Page 6: ...6 ...
Page 7: ...1 1 Warnings Warnings 1 ...
Page 8: ...1 2 Warnings ...
Page 11: ...Overview 2 1 Overview 2 ...
Page 12: ...2 2 Overview ...
Page 15: ...Overview 2 5 ...
Page 31: ...Installation 3 1 Installation 3 ...
Page 32: ...Installation 3 2 ...
Page 58: ...Installation 3 28 Notes ...
Page 67: ...Operation 4 1 Operation 4 ...
Page 68: ...Operation 4 2 ...
Page 83: ...Operation 4 17 Notes ...
Page 90: ...Operation 4 24 ...
Page 91: ...Screen Map 5 1 Screen Map 5 ...
Page 92: ...5 2 Screen Map ...
Page 94: ...5 4 Screen Map ...
Page 95: ...Run Monitor 6 1 Run Monitor 6 ...
Page 96: ...Run Monitor 6 2 ...
Page 103: ...Totalizers 7 1 Totalizers 7 ...
Page 104: ...Totalizers 7 2 ...
Page 108: ...Totalizers 7 6 ...
Page 109: ...System Configuration 8 1 System Configuration 8 ...
Page 110: ...System Configuration 8 2 ...
Page 142: ...System Configuration 8 34 ...
Page 143: ...Recipe Setup 9 1 Recipe Setup 9 ...
Page 144: ...Recipe Setup 9 2 ...
Page 165: ...10 1 Troubleshooting Troubleshooting 10 ...
Page 166: ...10 2 Troubleshooting ...
Page 182: ...10 18 Troubleshooting ...
Page 183: ...11 1 Service Service 11 ...
Page 184: ...11 2 Service ...
Page 192: ...11 10 Service ...
Page 193: ...12 1 Parts Parts 12 ...
Page 194: ...12 2 Parts ...
Page 207: ...12 15 Parts Notes ...
Page 228: ...12 36 Parts ...
Page 229: ...13 1 Utilities Software Utilities Software 13 ...
Page 230: ...13 2 Utilities Software ...
Page 254: ...13 26 Utilities Software ...
Page 255: ...14 1 Technical Data Technical Data 14 ...
Page 256: ...14 2 Technical Data ...
Page 259: ...14 5 Technical Data Notes ...