Run Monitor
6–3
Run Monitor
Screens
Information
Home Screen
Graco PrecisionMix II 3K (R)
Version X.XX
HOME SCREEN
Station: 1
1. RUN MONITOR
2. TOTALIZERS
3. RECIPE SETUP
4. SYSTEM CONFIGURATION
Select a menu item and press enter: > 1
Type in 1 , then
.
Press the next screen
or previous screen
arrow key to move forward or backward
to the desired Run Monitor screen.
Press the HOME key
to return to the
HOME screen.
This is the HOME screen where you choose which
system function to enter.
RUN MONITOR (#1) has the normal operating
screens.
TOTALIZERS (#2) has the screens with information
on material usage on the selected recipe.
RECIPE SETUP (#3) screens allow you to setup
“recipes” (ratio programs) for a variety of fluids.
SYSTEM CONFIGURATION (#4) screens allow
you to setup the controller to operate according to
your system requirements.
Selecting #1 on the Home Screen will bring up the first
Run Monitor screen (RM1 – Target/Actual). The run
monitor screens allow you to monitor the status of the
system. The readings will be displayed in either cubic
centimeters (cc), liters (l), ounces (oz), and/or gallons
(gal), depending on how the system has been config-
ured.
RM1
Target/Actual
RUN MONITOR
00/00/00
MIX RATIO
(A:B, C:B)
COMPONENT
VOLUMES
JOB
TOTALS
Recipe: 1
Desired
AB
0.00:1
CB
0.00:1
Target
A
0.0
B
0.0
C
0.0
COMPONENT A =
COMPONENT B =
COMPONENT C =
SOLVENT =
Station:
1
00:00
Actual
0.00:1
0.00:1
Actual
0.0 cc
0.0 cc
0.0 cc
000000 cc
000000 cc
000000 cc
000000 cc
Mix Ratios
Desired Ratio is the ratio entered during recipe setup.
Actual Ratio is a ratio the system actually dispensed
on the last cycle.
Component Volumes
Target (left hand column) is the desired volumes of
Component A, Component B, and Component C that
the controller will request.
Actual (right hand column) shows the quantities of
Component A, Component B, and Component C as
they are being dispensed.
Component Volumes are always measured in
cubic centimeters.
Job Totals
Displays total volume for the current job of Component
A, Component B, Component C, and Solvent (if a sol-
vent valve is installed and configured). The job totals
can be changed to read in ounces during system con-
figuration. See page 8–6.
Summary of Contents for PrecisionMix ii
Page 6: ...6 ...
Page 7: ...1 1 Warnings Warnings 1 ...
Page 8: ...1 2 Warnings ...
Page 11: ...Overview 2 1 Overview 2 ...
Page 12: ...2 2 Overview ...
Page 15: ...Overview 2 5 ...
Page 31: ...Installation 3 1 Installation 3 ...
Page 32: ...Installation 3 2 ...
Page 58: ...Installation 3 28 Notes ...
Page 67: ...Operation 4 1 Operation 4 ...
Page 68: ...Operation 4 2 ...
Page 83: ...Operation 4 17 Notes ...
Page 90: ...Operation 4 24 ...
Page 91: ...Screen Map 5 1 Screen Map 5 ...
Page 92: ...5 2 Screen Map ...
Page 94: ...5 4 Screen Map ...
Page 95: ...Run Monitor 6 1 Run Monitor 6 ...
Page 96: ...Run Monitor 6 2 ...
Page 103: ...Totalizers 7 1 Totalizers 7 ...
Page 104: ...Totalizers 7 2 ...
Page 108: ...Totalizers 7 6 ...
Page 109: ...System Configuration 8 1 System Configuration 8 ...
Page 110: ...System Configuration 8 2 ...
Page 142: ...System Configuration 8 34 ...
Page 143: ...Recipe Setup 9 1 Recipe Setup 9 ...
Page 144: ...Recipe Setup 9 2 ...
Page 165: ...10 1 Troubleshooting Troubleshooting 10 ...
Page 166: ...10 2 Troubleshooting ...
Page 182: ...10 18 Troubleshooting ...
Page 183: ...11 1 Service Service 11 ...
Page 184: ...11 2 Service ...
Page 192: ...11 10 Service ...
Page 193: ...12 1 Parts Parts 12 ...
Page 194: ...12 2 Parts ...
Page 207: ...12 15 Parts Notes ...
Page 228: ...12 36 Parts ...
Page 229: ...13 1 Utilities Software Utilities Software 13 ...
Page 230: ...13 2 Utilities Software ...
Page 254: ...13 26 Utilities Software ...
Page 255: ...14 1 Technical Data Technical Data 14 ...
Page 256: ...14 2 Technical Data ...
Page 259: ...14 5 Technical Data Notes ...