APPENDIX D: MISCELLANEOUS
REVISION HISTORY
L60 LINE PHASE COMPARISON SYSTEM – INSTRUCTION MANUAL
D-3
D
Table D-3: Major changes for L60 manual version AF1 (English)
Table D-4: Major changes for L60 manual version AE3 (English)
3-16
Added contact input and contact output modules 6W and 6X to Table 3-3 Contact Input and Output Module Assignments and
to Figure 3-16 Contact Input and Output Module Wiring (Sheet 3 of 3)
5-338
Updated Thermal Overload Protection Logic diagram
Page
Description
---
General revision
---
Updated "faceplate" to "front panel" for consistency and to reflect web site
---
Added graphical front panel option to order codes and specifications in chapter 2, Interfaces chapter 4, Settings chapter 5,
Actual Values chapter 6
---
Added PEAP-GTC and PAP protocols for authenticating user logins when using a RADIUS server. Added to Settings > Product
Setup > Security > RADIUS Authentication Method and to Modbus memory map and F codes.
---
Updated Contact Inputs from 96 to 120 and Contact Outputs from 64 to 72 in Product Description in chapter 2 and FlexLogic
operands table in chapter 5
---
Updated Neutral Time Overcurrent element number from 2 to 6 in FlexLogic operands table, settings, features per product
table, Modbus memory map
---
Updated Phase Time Overcurrent element number from 2 to 6 in FlexLogic operands table, settings, features per product
table, Modbus memory map
---
Updated Current CT Settings number from 4 to 6 in FlexLogic operands table, settings, features per product table, and
Modbus memory map
---
Updated Ground Instantaneous number from 4 to 12 in FlexLogic operands table, settings, features per product table,
Modbus memory map
---
Updated Ground Time Overcurrent number from 2 to 6 in FlexLogic operands table, settings, features per product table,
Modbus memory map
---
Updated Phase Instantaneous Overcurrent number from 4 to 12 in FlexLogic operands table, settings, features per product
table, Modbus memory map
---
Updated Neutral Instantaneous Overcurrent from 4 to 12 in FlexLogic operands table, settings, features per product table,
Modbus memory map
2-
Updated order code tables
3-36
Updated RS422 and Fiber Interface Connection figure for the clock channels (from 7a and 7b to 1a and 1b)
3-67
Added Connect to a D400 Gateway section
4-43
Updated LED Labelling instructions for the new Front Panel Label Designer
4-50
Added Standard Front Panel section for labelling LEDs and pushbuttons
5-105
Added USB Port section to enable/disable the USB port on the graphical front panel
5-122
Updated User-programmable Pushbuttons section as per specifications
5-143
Updated Breakers section as per specifications
5-149
Updated Disconnect Switches section as per specifications
10-5
Added Convert Device Settings section
10-7
Added Copy Settings to Other Device section
10-15
Added Replace Front Panel section for retrofit with the new graphical front panel
A-
Updated FlexAnalog table
Page
Description
---
General revision
2-
Updated order codes
10-5
Added Copy Settings to Other Device section
Page
Description