F - 160 Operation and Maintenance Manual
© GBC Pro - Tech August 1999
Page 5 - 2
Operations
( 5 ) BOT. TEMP. DISPLAY : The display will show
the set point temperature of the bottom main roller as
the default display. When the bottom roller temperature
has reached in the +/- 10
o
F range of the set point, the
display will be solid. When outside of this range, the
display will flash.
T O P T E M P .
B O T . T E M P
S L E E P
3 2
3 2
5
( 6 ) BOT. TEMP.
s
: When pressed, will increase
the set point value of the bottom main roller in
increments of 2 degrees. If this key is held down, it will
only increase to the maximum temperature setting of
290
o
F ( 143
o
C ).
T O P T E M P .
B O T . T E M P
S L E E P
6 8
6 8
6
( 7 ) BOT. TEMP.
t
: When pressed, will decrease
the set point value of the bottom main roller in
increments of 2 degrees. If held down, it will decrease
to the minimum temperature setting of 68
o
F ( 20
o
C ).
T O P T E M P .
B O T . T E M P
S L E E P
6 8
6 8
7
( 8 ) GAP DISPLAY : Displays the current main roller
nip opening. The nip has a range of 0 to 1” gap.
G A P
P R E S S U R E
1/4
8
( 9 ) GAP
s
: When pressed, will increase the gap by
1/16 in. increments. If held down, it will automatically
increase the gap by 1/16 in. increments until it has
reached a maximum opening of 1 in. on the GAP
DISPLAY.
G A P
P R E S S U R E
1/4
9
( 10 ) GAP
t
: When pressed, will decrease the gap
by 1/16 in. increments. If held down, it will
automatically decrease the gap by 1/16 in. increments
until it has reached a minimum opening of 0 in. on the
GAP DISPLAY.
G A P
P R E S S U R E
1/4
1 0