F - 160 Operation and Maintenance Manual
© GBC Pro - Tech August 1999
Page 4 - 18
Installation
4.8.1 Control panel
a) Press TOP TEMP.
s
to a value of 120
o
F
( 48
o
C ). TOP TEMP DISPLAY begins
flashing.
T O P T E M P .
B O T . T E M P
S L E E P
6 8
1 2 0
b) Press BOT TEMP
s
to a value of 120
o
F
( 48
o
C ). BOT TEMP DISPLAY begins
flashing.
T O P T E M P .
B O T . T E M P
S L E E P
1 2 0
1 2 0
c) Press GAP
t
once. GAP DISPLAY
decreases 1/16th of an inch per press. The
upper main roller moves accordingly. Once to
“0”, the upper main roller is contacting the
lower main roller.
G A P
P R E S S U R E
1 - 0
d) Press GAP
s
. GAP DISPLAY increases
1/16th of an inch per press. The upper main roll
moves accordingly. Once to “1”, the upper
main roller stops.
G A P
P R E S S U R E
0 - 1
e) Press and hold PRESSURE
t
. The upper
main roller travels in a constant downward
motion. Once making contact with the lower
main roller, the bars turn solid one at a time until
all 10 bars are solid.
G A P
P R E S S U R E
0
f) Press and hold PRESSURE s. The upper main
roller travels in a constant upward motion. The
pressure bars turn hollow one at a time until no
bars are solid and GAP DISPLAY changes to
“1” then stops.
G A P
P R E S S U R E
1