Specifications
F - 160 Operation and Maintenance Manual
© GBC Pro - Tech August 1999
Page 3 - 2
Section 3.3 Function
Speed :
Motor :
Heating Capabilities :
Controls :
Job Save :
Roll Design :
Section 3.4 Electrical
United States :
Europe :
B.T.U. output :
Heater Wattages :
Amperage Draw :
D/C Voltage used :
A/C Voltage used:
• 0 - 15 ft / min ( 0 - 4.6 m / min )
• 2-1/4 horse power drive motor
• Bi-directional D.C. motor
• 68
o
F - 290
o
F ( 20
o
C - 143
o
C )
• Front control panel
• Variable speed footswitch
• Save up to 9 job parameters
• High release silicone rolls
• 230 - 240 VAC, 50/60 Hz, single phase, 55 amps.
• 230 - 240 VAC, Wye 3 phase, 32 amps/ phase
• 31,732 B.T.U. / hour
• 4650 watts per heater
• No heat, motor only : 1 - 3 amps
• Top heat and motor : 20 - 23 amps
• Both heat and motor : 40 - 43 amps
• 24 vdc
• 12 vdc isolated x 2
• 24 vdc isolated
• 230 vac ( minimum )
Requirements