_____________________________________________________Chapter 5 - Troubleshooting, Page 5-11
Smoke Control – ESP Cells
Symptom
Probable Cause
Corrective Action
1.
Fluctuating green ESP Cell
Status Light.
1.
Normally this is a temporary
condition, lasting until the
Cells are dry, immediately
following a Wash Cycle.
None required.
2.
Green ESP Cell Status Light
off.
1.
Plunger Safety Switch Failure. 1.
Refer to Testing Plunger
Safety Switch instructions on
page 6-52.
1.
Voltage not getting to the
Cells.
1. Check to ensure that all lead
wires are connected to the
Cells.
1.
Possible Transformer failure.
1.
Refer to Testing Transformer
Voltage on page 6-55.
1.
Faulty Cell. Possible causes
are:
a.
Grease build up on plates
or insulators.
b.
Foreign material lodged
between plates.
c.
Broken Ionizer wire.
For all three possible causes first
perform the tests following the
test flow chart on page 6-46.
1.
Remove any foreign material
between Cell plates.
2.
Remove grease buildup by
cleaning or replace the Cell.
2.
Replace missing or broken
ionizing wires following the
instructions on page 6-51.
Table T-5-11-1