![GAYLORD CG3-UVi-SPC Series Technical Manual Download Page 153](http://html.mh-extra.com/html/gaylord/cg3-uvi-spc-series/cg3-uvi-spc-series_technical-manual_570445153.webp)
Appendix D – Ventilator Start-Up Inspection and Tests, Page D-6_________________________________
Page 4 of 6
Ventilator Start-Up Inspection and Test Report
For Gaylord Model CG3-UVi-SPC Series Ventilators
Wash Control Cabinet Check
a.
Any water leaks …………………………………………………………………….…………………..……. ____ Yes ____ No
b.
Detergent pump is primed and pumping …………………………………….……………..……. ____ Yes ____ No
c.
Water pressure is: (40 psi Min. to 80 psi Max.) …..….………………………….………………………….. ____ psi
d.
Water temperature is: (160° F. Min. to 180° F. Max.) ………………….……………..…………………… ____° F.
e.
Brand of detergent used ……………………………………………___________________________________
Conclusion of Wash Cycle Check
a.
At conclusion of the Wash Cycle the water shut off .………………………………..…….… ____ Yes ____ No
b.
Did the damper stay closed in the forward position (CG3-UVi-SPC and CG3-UVi-FDL only).
…………………………………………………………………………………………………………….…….………. ____ Yes ____No
Internal Fire Mode Test
Important Note:
This test only applies to the standard Model CG3-UVi-SPC. If the Ventilator Model
number includes FDL, FDT, FDD, or ND no test is required. Proceed to next test.
Caution: Performing this test may set off the building fire alarm system and may notify the fire
department. Notifying building management/maintenance and disabling the building alarm system is
necessary.
The standard model CG3-UVi-SPC Ventilator has a damper at the air inlet slot and includes a thermostat,
that when activated by high heat or fire, closes the damper to the fire position. This is called an Internal
Fire Mode.
To test the Internal Fire Mode, push the Fire Mode Test button on the Gaylord Command Center. The
following should occur:
1.
The exhaust fan shut off. ………………………………………………………………………………….……. ____ Yes ____ No
2.
The make-up air shut off. ……………………………………………………………………………………..… ____ Yes ____ No
3.
The damper closed to the rear, the Fire Mode position. ………………………………………... ____ Yes ____ No
4.
The Wash Sprays should be off. ……………………………………………………………………………… ____ Off ____ On
5.
The UV System shut off. ……………………………………………………………………..……………….…. ____ Yes ____ No
6.
Gaylord Command Center screen displays that there is a fire in the Ventilator. ……………………
…………………………………………………………………………………………………………………..…………… ____ Yes ____ No