Chapter 8 Operation and Maintenance
iRMC reports sensor status: CRITICAL
Voltages
The voltage is abnormal. Power off the server and unplug the
power cable. After that, turn the power back on. If the message
still appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of the "Start Guide".
iRMC reports sensor status: WARNING
Voltages
iRMC reports sensor status: CRITICAL
Battery
The battery voltage is abnormal. Power off the server and
unplug the power cable. After that, turn the power back on. If
the message still appears, the baseboard or battery must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
iRMC reports sensor status: WARNING
Battery
iRMC reports sensor status: CRITICAL FAN*
CPU (*: 1 to 6)
CPU fan error. Check that there is nothing obstructing the fan
rotation. If the message still appears even though there is no
obstacle, the CPU fan or baseboard must be replaced. Contact an
office listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING
FAN* CPU (*: 1 to 6)
iRMC reports sensor status: CRITICAL FAN*
SYS (*: 1 or 2)
System fan error. Check that there is nothing obstructing the fan
rotation. If the message still appears even though there is no
obstacle, the system fan or baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING
FAN* SYS (*: 1 or 2)
iRMC reports sensor status: CRITICAL FAN
PSU* (*: 1 or 2)
PSU fan error. Check that there is nothing obstructing the fan
rotation. If the message still appears even though there is no
obstacle, the PSU fan or baseboard must be replaced. Contact an
office listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING FAN
PSU* (*: 1 or 2)
iRMC reports sensor status: CRITICAL
DIMM-*A (*: 1 to 3)
Memory error. Replace the displayed memory module in the
memory bank. If the message still appears, the memory board 1
or baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING
DIMM-*A (*: 1 to 3)
iRMC reports sensor status: CRITICAL
DIMM-*B (*: 1 to 3)
iRMC reports sensor status: WARNING
DIMM-*B (*: 1 to 3)
iRMC reports sensor status: CRITICAL
DIMM-*C (*: 1 to 3)
Memory error. Replace the displayed memory module in the
memory bank. If the message still appears, the memory board 2
or baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING
DIMM-*C (*: 1 to 3)
iRMC reports sensor status: CRITICAL
DIMM-*D (*: 1 to 3)
iRMC reports sensor status: WARNING
DIMM-*D (*: 1 to 3)
iRMC reports sensor status: CRITICAL PCI
Slot* (*: 1 to 7)
The PCI card is abnormal. Check the error log and specify the
error location, and replace the expansion card. If the message
still appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of the "Start Guide".
iRMC reports sensor status: WARNING PCI
Slot* (*: 1 to 7)
iRMC reports sensor status: CRITICAL CPU*
(*: 1 or 2)
The CPU is abnormal. Check the error log and replace the faulty
CPU. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
iRMC reports sensor status: WARNING
CPU* (*: 1 or 2))
table: List of POST error messages
Message
Description
Summary of Contents for Primergy RX300 S4
Page 12: ...12 ...
Page 38: ...38 Chapter 1 Overview ...
Page 72: ...72 Chapter 3 OS Installation ...
Page 124: ...124 Chapter 4 Operations after OS Installation ...
Page 132: ...132 Chapter 5 High Reliability Tools ...
Page 180: ...180 Chapter 6 Installing Internal Options ...
Page 266: ...266 ...