56
Chapter 3 OS Installation
13
Restart the system.
For Windows Server 2008
The system automatically restarts when a message notifies completion of installation.
After restarting, enter the set password to login.
For Windows Server 2003
Press the [Enter] key when a message notifies completion of installation.
Click [Start] – [Shutdown] to restart the system.
After restarting, enter the set password to login.
14
Perform the settings for the RAID management tool (ServerView RAID).
For the setting procedures, refer to the manuals in Array Controller Document & Tool CD.
• Settings of an array administrator account
The Windows user account is required when using ServerView RAID. Create a group named
"raid-adm", and an account with any name for an array administrator within the group "raid-
adm".
• Setting the HDD check scheduler
When using the SAS RAID Ctrl (MegaRAID SAS), change the settings for the HDD check
scheduler according to the operation that is required. It is set to 12:00 everyday as default.
• Configuration of Battery Recalibration Scheduler
When using a SAS RAID Ctrl (MegaRAID SAS) together with a battery backup unit, change
the settings of Battery Recalibration Scheduler according to the operation that is required. The
default setting is 11:00 on the first of every month.
15
Perform settings for ServerView.
Refer to "2.4 Checking after Installation" in "ServerView User's Guide" to perform the necessary
settings.
The server setup and OS installation have been completed.
Refer to "Chapter 4 Operations after OS Installation" (
p.73) and perform necessary procedures before
starting server operations.
Summary of Contents for Primergy RX300 S4
Page 12: ...12 ...
Page 38: ...38 Chapter 1 Overview ...
Page 72: ...72 Chapter 3 OS Installation ...
Page 124: ...124 Chapter 4 Operations after OS Installation ...
Page 132: ...132 Chapter 5 High Reliability Tools ...
Page 180: ...180 Chapter 6 Installing Internal Options ...
Page 266: ...266 ...