219
PRIMERGY RX300 S4 User's Guide
Application CPU timeout error
The CPU is abnormal. Power off the server and turn it back on.
If the message still appears, check the error log and replace the
CPU if it is at fault. Or the baseboard must be replaced. Contact
an office listed in the "Contact Information" of the "Start
Guide".
Server Management Configuration NVRam
Bad - defaults loaded!
The contents of NVRam is abnormal.
Correct the current settings on the BIOS Setup Utility or turn the
setting back to the default. When the correct setting values are
saved by Server Management Tools, restore it. If the message
still appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of the "Start Guide".
Baseboard Management Controller Error
The baseboard management controller is abnormal. Power off
the server and turn it back on. If the message still appears, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of the "Start Guide".
PCI Express link width degraded
The PCI Express card is abnormal. Replace the PCI Express
card. If the message still appears, the baseboard or CPU must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
USB Over current on HC
The current value of the USB onboard device is abnormal.
Power off the server and turn it back on. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of the "Start Guide".
Uncorrected CPU Machine Check
Architecture (MCA) error
The CPU is abnormal. Power off the server and turn it back on.
If the message still appears, check the error log and replace the
CPU if it is at fault. Or the baseboard must be replaced. Contact
an office listed in the "Contact Information" of the "Start
Guide".
Memory configuration has changed - Run
SETUP
The memory configuration has changed. This message may
appear after replacing the baseboard or memory module. Select
[Yes] for the [Reset Configuration Data] setting on the "7.2.5
Advanced Menu" (
p.190) of the BIOS Setup Utility.
Memory module failed! This module is no
longer available for the operating system.
The memory is abnormal. Replace the memory module. If the
message still appears, the memory board or baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
CPU disabled! CPU is no longer available for
the operating system.
The CPU is abnormal. Replace the CPU. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of the "Start Guide".
Resource Conflict
The hardware resource is abnormal. Power off the server and
turn it back on. If the message still appears, select [Yes] for the
[Reset Configuration Data] setting on the "7.2.5 Advanced
Menu" (
p.190) of the BIOS Setup Utility. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of the "Start Guide".
IRQ not configured
Expansion ROM not initialized
Allocation error static node#
iRMC reports sensor status: CRITICAL
TEMP
The temperature is abnormal. Check the environment where the
server is used. If the message still appears, check the error log.
The faulty part must be replaced. Contact an office listed in the
"Contact Information" of the "Start Guide".
iRMC reports sensor status: WARNING
TEMP
table: List of POST error messages
Message
Description
Summary of Contents for Primergy RX300 S4
Page 12: ...12 ...
Page 38: ...38 Chapter 1 Overview ...
Page 72: ...72 Chapter 3 OS Installation ...
Page 124: ...124 Chapter 4 Operations after OS Installation ...
Page 132: ...132 Chapter 5 High Reliability Tools ...
Page 180: ...180 Chapter 6 Installing Internal Options ...
Page 266: ...266 ...