![Fujitsu Siemens Computers PRIMERGY RX100 S4 User Manual Download Page 197](http://html.mh-extra.com/html/fujitsu-siemens-computers/primergy-rx100-s4/primergy-rx100-s4_user-manual_2344450197.webp)
197
PRIMERGY RX100 S4 User’s Guide
Inst
a
llin
g I
n
te
rn
al O
p
tions
7
7.6.1 Installation Location of Internal Hard Disk Unit
■
SCSI-ID of Internal Hard Disk Unit
The internal hard disk unit is installed in 3.5inch storage bay.
Bay numbers are as follows.
Install the internal hard disk units in the order of bay 1 and bay 2.
7.6.2 Installable Internal Hard Disk Units and Notes
The following internal hard disk units can be installed on this server.
■
Notes on Configuring Array
Install internal hard disk units with the same model number on bay1 and bay2.
■
Slot Number
Slot numbers displayed on RAID Management Tool and their corresponding hard disk bay numbers are
as follows.
table: List of Installable Internal Hard Disk Units
Product name
Model
Overview
HDD SAS 15k 73GB hot plug 3.5inch
PG-HDB75A
73.4GB, 15,000rpm, SAS
3.5 inch, Hot Pluggable
HDD SAS 15k 147GB hot plug 3.5inch
PG-HDB45A
146.8GB, 15,000rpm, SAS
3.5 inch, Hot Pluggable
Bay number
1
2
Slot number
0
1
Bay 2
Bay 1