137
Checks to perform:
IMPORTANT
The appliance remains in alarm status until the mains frequency returns
to the correct values or the appliance is switched Off. Only the family of
the alarm is displayed and the Diagnostics Mode cannot be accessed. The
complete alarm can only be read when the situation has normalized.
Checks to perform:
Is the supply line disturbed or the main voltage out of
range?
(V>264V
rms
for 240V system, (V>138V
rms
for 120V system
Replace the Electronic Control Board and repeat the
Diagnostic Cycle to check for any further alarms.
NO
Have the electrical system of the home checked/
repaired by the proper Body.
Y
E
S
EA3
EA3: Voltage too Low
EA3
Line voltage too Low or Electronic Control Board fault.
WARNING
Check that all the connectors are correctly inserted
Is the supply line disturbed or the main voltage out of
range?
(V<180V
rms
for 240V system, (V<90V
rms
for 120V system
Replace the Electronic Control Board and repeat the
Diagnostic Cycle to check for any further alarms.
NO
Have the electrical system of the home checked /
repaired by the proper Body.
Y
E
S
EA5
EA5: Line amplitude sensing failure on main board
EA5
Main board, microprocessor and software corrupted.
WARNING
Check that all the connectors are correctly inserted
Replace the Electronic Control Board and repeat the Diagnostic Cycle to check for any further alarms.
Summary of Contents for FFLE3911QW
Page 1: ...Publication 5995666392 October 2015 Technical Service Manual Laundry Center ...
Page 2: ...I ...
Page 9: ...8 3 Product Features ...
Page 14: ...13 5 1 FFLE3911QW 5 1 1 Upper Cabinet Drum Heater 5 Exploded View and List of Parts ...
Page 17: ...16 5 1 2 Motor Blower Belt ...
Page 19: ...18 5 1 3 Control Panel ...
Page 21: ...20 5 2 FFLG4033QW 5 2 1 Upper Cabinet Drum Heater ...
Page 24: ...23 5 2 2 Motor Blower Belt ...
Page 27: ...26 5 2 3 Control Panel ...
Page 32: ...31 5 3 3 Wash Assembly POS NO DESCRIPTION 14 Screw 2 PLCS 15 Lock Hub Functional parts ...
Page 33: ...32 5 3 4 Cabinet Assembly ...
Page 69: ...68 User Interface of Laundry Center FFLG4033QW ...
Page 76: ...75 8 6 Wiring Diagram FFLE3911QW Electric Dryer Model ...
Page 77: ...76 8 7 Wiring Diagram FFLG4033QW Gas Dryer Model ...
Page 78: ...77 8 8 Wiring Diagram FFLE3911QW and FFLG4033QW Washer Model ...
Page 91: ...90 Wiring Diagram FFLE3911QW Wiring Diagram FFLG4033QW ...
Page 125: ...124 ...
Page 161: ...160 ...
Page 165: ...164 ...
Page 168: ...167 ...
Page 170: ...169 ...
Page 179: ...178 ...
Page 181: ...180 ...
Page 183: ...182 ...