Technical Specifications
Introduction
1-12
ModuSys 2000 Kernel
Table 9: Reliability Estimates for ModuSys 2000 Kernels
Part Number
Description
MTBF
1
(hrs)
Reliability at 25°C
Reliability at 40°C
Reliability at 50°C
1
Air temperatures are inlet ambient to the ModuSys enclosure. These estimates are
provided to assist in maintenance planning; they do not supersede or affect the
published warranty. They exclude mechanical wearout, as of fans and disk. These
estimates have been prepared in general accordance with Telcordia Issue 6 Method
1, case 3, including use of the RELEX 7.1 estimation tool.
Summary of Contents for MODUSYS 2000 Kernel
Page 5: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 17: ......
Page 21: ......
Page 25: ......
Page 26: ...1 Introduction...
Page 27: ......
Page 50: ...2 Backplane...
Page 51: ......
Page 64: ...3 Accessing Internal Components...
Page 65: ......
Page 71: ......
Page 72: ...4 Installing and Removing Storage Devices...
Page 73: ......
Page 84: ...5 Installing and Removing Option Boards...
Page 85: ......
Page 98: ...6 Replacing Module Unit Components...
Page 99: ......
Page 108: ...Replacing Module Unit Components Replacing the Power Supply Unit ModuSys 2000 Kernel 6 11...
Page 109: ......
Page 110: ...A Assembly Drawings...
Page 111: ......
Page 112: ...Assembly Drawings ModuSys 2000 Kernel A 3...