FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
95
of
146
V
Read digital outputs
Command
: [ADR][V]
Response
: [ADR][V][STATUS][Outputs]
Example :
Command
: 01V
Response
: 01VA03
(Output 2 and Output 1 are active)
01VA96
(Output 8,5,3,2 are active)
01VAFF
(All 8 outputs are active)
01VN
(Could not read outputs)
Comments
:
Data length change according to number of digital outputs.
Outputs are implemented to ASCII char of 4-bit
. ‘1111’ is implemented to char ‘F’.
W
Write ( Set/Reset ) digital outputs
Command
: [ADR][W][Outputs]
Response
: [ADR][W][STATUS]
Example :
Command
: 01W96
Response
: 01WA
(Outputs 8,5,3,2 are activated)
01WN
(Outputs could not be activated)
Comments
:
Data length change according to number of digital outputs.
Outputs are implemented to ASCII char of 4-bit
. ‘1111’ outputs are implemented to char F’.
The parameter of output(s) must be programmed as ‘FBUS’ for this feature
( Page 59 )
.
X
Read weight value in increased resolution
Command
: [ADR][X]
Response
: [ADR][X][STATUS][SIGN][WEIGHT VALUE]
Example :
Command
: 01X
Response
: 01XS+00123.41 (weight is stable and 123.41) or
01XD+00123.41 (weight is dynamic and 123.41) or
01XE
(Error)
Comments
:
The response includes weight data with divided the increment to 10.
Z
Zero
Command
: [ADR][Z]
Response
: [ADR][Z][A]
(Zeroed)
[ADR][Z][N]
(Zeroing could not be operated)
[ADR][Z][X]
(Zeroing is disabled)
Comments
:
Zero command cannot work in net weighing.
Weight must be in zeroing range for all operating modes.
Status must be stable in 2 seconds time out delay. If so, Ack is send.
If it cannot be stable in time out delay, Nack is send
OUTPUTS
O
UT
-8
O
UT
-7
O
UT
-6
O
UT
-5
O
UT
-4
O
UT
-3
O
UT
-2
O
UT
-1
Bit wise
1
0
0
1
0
1
1
0
ASCII
9
6
OUTPUTS
O
UT
-8
O
UT
-7
O
UT
-6
O
UT
-5
O
UT
-4
O
UT
-3
O
UT
-2
O
UT
-1
Bit wise
1
0
0
1
0
1
1
0
ASCII
9
6