S NET Free setpoint of net weight
The digital output is activated with comparing the set point value and net weight value as seen below.
As an example,
if SP1
SP1
LOW
SP1
HIGH
SP2
SP2
LOW
SP2
HIGH
= 100 kg or
= 100 kg
= 150 kg
= -200kg or
= -200kg
= -225kg
BAS-HI
Basic, active high
Output is high if net weight is heavier than
setpoint.
( Default )
BAS-LO
Basic, active low
Output is low if net weight is heavier than
setpoint.
THR-HI
Threshold, active high
Output goes to high if net weight is heavier
than setpoint high. Returns the low if the
weight is less than setpoint low.