FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
136
of
146
PLC Output to FT-111 Input
Bitwise of a Dword:
Unsigned
Long
(R/W)
B63 B62 B61 B60 B59 B58 B57 B56 B55 B54 B53 B52 B51 B50 B49 B48
B47 B46 B45 B44 B43 B42 B41 B40 B39 B38 B37 B36 B35 B34 B33 B32
B31 B30 B29 B28 B27 B26 B25 B24 B23 B22 B21 B20 B19 B18 B17 B16
B15 B14 B13 B12 B11 B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
RxPDO 1
(R_UL1)
Out
5
Out
4
Out
3
Out
2
Out
1
Expanded Commands List
Not in use
Command List
Read Data Selection
New
CMD
B37-B33 bits defines the usage of this Dword.
PLC Output to FT-111 Input RxPDO 1 (R_UL1)
Bit Number RxPDO 1 (R_UL1) descriptions
B63 … B56
Set / Reset digital outputs
B55 … B48
Expanded Commands List ( Refer to
B47 … B43
Not in use
B42 … B38
Command
List
Bin
Dec
Commands
00000
0
None command is activated
00001
1
Zero
00010
2
Tare
00011
3
Clear
00100
4
00101
5
Adjust zero calibration
Calibration
00110
6
Adjust span calibration
(1)
00111
7
Total Load Cell Capacity
(1)
eCal
Coefficients
Refer to par. [613]
01000
8
Average mV/V value
(1)
01001
9
Dead Load value
(1)
01010
10
Save the coefficients of eCal
01011
11
CN (Label number)
(1)
01100
01110
12
14
Not used
01111
15
Set Point-1 (High)
10000
16
Set Point-2 (High)
10001
17
Set Point-3 (High)
10010
18
Set Point-4 (High)
10011
19
Set Point-5 (High)