FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
81
of
146
S GRO Free setpoint of gross weight
The digital output is activated with comparing the set point and weight at gross weight indication as seen
below.
As an example,
if SP1
SP1
LOW
SP1
HIGH
= 100 kg or
= 100 kg
= 150 kg.
BAS-HI
Basic, active high
Output is high if gross weight is heavier than
setpoint.
( Default )
BAS-LO
Basic, active low
Output is low if gross weight is heavier than
setpoint.
THR-HI
Threshold, active high
Output goes to high if gross weight is heavier
than setpoint high. Returns the low if the
weight is less than setpoint low.
THR-LOW
Threshold, active low
Output goes to low if gross weight is heavier
than setpoint high. Returns the high if the
weight is less than setpoint low.
VIN-HI
Window, active high
Output goes to high if gross weight is between
setpoint high and setpoint low.
VIN-LOW
Window, active low
Output goes to low if gross weight is between
setpoint high and setpoint low.
SPC1 Control mode-1
The digital outputs are activated as seen below, if setpoints are set up to Control mode-1 and their values
are entered consequently from setpoint 1 to the setpoint N how much needed.
Digital outputs which are not used at this mode can be programmed freely to any other function. For
example if SP5 is not needed to control, it can be programmed to the zero range to produce empty signal.