FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
77
of
146
THR-LOW
Threshold, active low
Output goes to low if indicated weight is
heavier than setpoint high. Returns the high if
the weight is less than setpoint low.
VIN-HI
Window, active high
Output goes to high if indicated weight is
between setpoint high and setpoint low.
VIN-LOW
Window, active low
Output goes to low if indicated weight is
between setpoint high and setpoint low.