FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
78
of
146
S ANE Free setpoint of absolute net weight
The digital output is activated with comparing the set point value and absolute net weight value as seen
below.
As an example,
if SP1
SP1
LOW
SP1
HIGH
= 100 kg or
= 100 kg
= 150 kg.
BAS-HI
Basic, active high
Output is high if absolute net weight is heavier
than setpoint.
( Default )
BAS-LO
Basic, active low
Output is low if absolute net weight is heavier
than setpoint.
THR-HI
Threshold, active high
Output goes to high if absolute net weight is
heavier than setpoint high. Returns the low if
the weight is less than setpoint low.
THR-LOW
Threshold, active low
Output goes to low if absolute net weight is
heavier than setpoint high. Returns the high if
the weight is less than setpoint low.
VIN-HI
Window, active high
Output goes to high if absolute net weight is
between setpoint high and setpoint low.
VIN-LOW
Window, active low
Output goes to low if absolute net weight is
between setpoint high and setpoint low.