FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
11
of
146
EtherNet/IP
(
opional))
Data rate
10 Mbit/s or 100 Mbit/s, full duplex
EDS file
Generic EDS-file provided
DLR (Device Level
Ring)
Available
TCP/IP settings
DHCP or manual IP assign over EtherX PC Software or by keys in programming
mode.
Device identity customization
Topology
Line, Bus, Star or Tree topology depending on physical media
Installation
Switched Ethernet transmission with shielded twisted pair cables and RJ-45
connectors.
Web client
Available
Isolation
Galvanically isolated bus electronics
Response speed
Up to 4 ms. response delay after read/write commands.
Remote IO
Digital inputs and outputs of the instrument can be programmed independently as
a Remote IO’s of PLC to control them over fieldbus.
EtherCAT
(
opional)
Data rate
100 Mbit/s, full duplex
ESI file
Generic ESI-file provided
Topology
Line, Tree, Star or Daisy-chain topology depending on physical media
Installation
Switched Ethernet transmission with shielded twisted pair cables and RJ-45
connectors.
Isolation
Galvanically isolated bus electronics
Response speed
Up to 4 ms. response delay after read/write commands.
Remote IO
Digital inputs and outputs of the instrument can be programmed independently as
a Remote IO’s of PLC to control them over fieldbus.
CC-Link
(
opional)
Data rate
156 kbit/s
– 10 Mbit/s (selectable)
Topology
Line with Trunkline, Branch structure and Termination at both Ends.
Installation
3 wires shielded twisted pair cable.
Max. Stations
Up to 64 stations per network
Isolation
Galvanically isolated bus electronics
Response speed
Up to 4 ms. response delay after read/write commands
Remote IO
Digital inputs and outputs of the instrument can be programmed independently as
a Remote IO’s of PLC to control them over fieldbus.
Powerlink
(
opional)
Compatibility
Supports Ethernet POWERLINK V2.0 Communication Profile Specification
version 1.2.0
Data rate
100 Mbit/s, half duplex