FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
10
of
146
Profibus DPV1
(
opional))
Data rate
Up to 12000 kbit/s with automatic baud rate detection
GSD file
Generic GSD-file provided
Topology
Depending on physical media
RS-485: segmented line topology without stubs
Installations
Shielded twisted pair cable
Line length depending on physical media and transmission speed
Max. Stations
up to 126 stations per network
Isolation
Galvanically isolated bus electronics
Response speed
Min. 4 ms response delay after read/write commands
Remote IO
Digital inputs and outputs of the instrument can be programmed independently as
a Remote IO’s of PLC to control them over fieldbus.
Profinet
(
opional)
Data rate
100 Mbit/s, full duplex
GSDML file
Generic GSDML-file provided
TCP/IP settings
DHCP or manual IP are assigned over EtherX PC Software or by keys in
programming mode. Device identity customization
Topology
Line, Bus, Star or Tree topology depending on physical media
Installation
Switched Ethernet transmission with shielded twisted pair cables and RJ-45
connectors.
Web client
Available
Isolation
Galvanically isolated bus electronics
Response speed
Min. 4 ms response delay after read/write commands
Remote IO
Digital inputs and outputs of the instrument can be programmed independently as
a Remote IO’s of PLC to control them over fieldbus.
CANopen
(
opional))
Data rate
10 kbit/s
– 1 Mbit/s (selectable) kbit/s
EDS file
Generic EDS-file provided
Topology
Line with Trunkline, Dropline structure and Termination at both Ends
Line length depending on baud rate 25
– 500 meter.
Installation
2 wire shielded twisted pair cable
Alternatively 4 wire with 24 Volt power over the bus
Max. Stations
Up to 127 stations per network
Isolation
Galvanically isolated bus electronics
Response speed
Min. 4 ms response delay after read/write commands
Remote IO
Digital inputs and outputs of the instrument can be programmed independently as
a Remote IO’s of PLC to control them over fieldbus.