[ 5-- SCALE ] Scale Block
This blocks are related with the measurement related parameters which are described the usage of the scale.
The most important parameter is 511 which limit the usage of the parameters in main blocks 5, 6 and 8. The
selections of this parameter are;
IND
Industrial weighing
Selections of parameters at set up and calibration are free
for industrial usage of the instrument.
INDG
Industrial weighing
only gross
Autozeroing, taring and power on zero are disabled.
(recommended for tank /silo weighing in gross.
INDN
Industrial weighing net
(taring can be enabled)
Autozeroing and power on zero are disabled.
(recommended for tank /silo weighing in gross
OIML
Approved scale
according to OIML
Metrology related parameters are restricted to limits of OIML
R76 and EU type approval of the instrument.
After setting parameter 511, even you set any parameter out of the accepted range of selection of par 511, it is
saved in the acceptable limit. For example, if taring is activated at INDG selection, it will be disabled while
exiting from set up. For approved scales, set the parameters in main blocks 5, 6 and 8 perform calibration
carefully due to sealing of the scale in legal usage.
[
5-- SCALE
]
SCALE RELATED PARAMETERS MAIN BLOCK
Press
key sequentially to access this main block,
or press key or
key to enter configuration
parameters,
or press
key to go to the next block,
or press
key to exit from programming.
[ 51- SET UP
]
SCALE SET UP
Press key or
key again to enter this menu.
Or press
key to go to the next sub-block.
[ 511 APROVAL
:
IND ] M Approval
IND
: Industrial. All parameters can be freely selected.
INDG
INDN
OIML
:
:
:
Industrial weighing of tank, hopper or silo in gross.
(Taring, AZTrack and Power on Zero are disabled)
Industrial weighing in Net of tank, hopper or silo.
(disabled AZT and Power on Zero, enabled Tare )
OIML approved scale.
[ 512 HIGHRES
: TOGG ] M High resolution
Page 37,
TEMP
TOGG
ALWA
:
:
:
Temporary indication with key.
Toggle. Start and end high resolution by pressing
key in sequence.
Always high resolution
[ 513 PWR ZERO
:
NO ] M Power on zero.
NO
2%
2%LK
10%
:
:
:
:
Disable.
± 2%
± 2%, [ POWER ON ZERO ERR ] prompt cannot
be erased. Call service.
± %10
15-5
20%
:
:
+ %15, - %5
± %20