58
Sanitizing the Blending System
1. Prepare sanitizer solution by mixing half a
packet (1 oz) of Stera-Sheen® Green Label
with one gallon of warm water (108°F /
42°C) until dissolved. Pour approximately
16 oz. of solution into a spray bottle.
2. Submerge the Gear Box, suspension
bracket, Gear Cartridge, spout adapter, and
Blending Head in approved sanitizer
solution and soak for 5 minutes.
3. Remove each part from the sanitizer
solution. Place the items on a tray to air dry.
4. Remove the cap and spray the cap and
syrup line manifold opening with approved
sanitizer solution. Allow them to sanitize for
at least 5 minutes.
5. Place the 9-Tube Assembly and manifold
cap on a sanitary tray to dry.
Assembling the Blending Assembly
The two Blending Head o-rings and the Gear
Cartridge are wear items and will need to be
replaced periodically. Check for wear
occasionally and always keep spares of these
items on hand in the Spare Parts Kit.
1. Place the Gear Cartridge into the Drive
Assembly Gear Box so that the gear teeth
line up with the gear inside the Drive
Assembly Gear Box.
2. Install the Blending Head onto the Drive
Assembly Gear Box and rotate off-center to
secure.
3. Insert the Drive Motor into the Drive
Assembly Gear Box so that all four locking
screws are seated properly and rotate the
motor clockwise to secure.
26068
26025
Summary of Contents for CTP 80CBB
Page 7: ...6 PAGE INTENTIONALLY LEFT BLANK ...
Page 9: ...8 General System Overview Figure 1 ...
Page 14: ...13 PAGE INTENTIONALLY LEFT BLANK ...
Page 15: ...14 Premium Blending Assembly and Related Parts Figure 3 ...
Page 17: ...16 Syrup Pump and Related Parts Figure 4 ...
Page 19: ...18 Sanitizer Pump and Related Parts Figure 5 ...
Page 22: ...21 PAGE INTENTIONALLY LEFT BLANK ...
Page 23: ...22 Electronic Parts and Connections Figure 6 ...
Page 25: ...24 Spare Parts Kit Figure 7 ...
Page 26: ...25 PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...49 PAGE INTENTIONALLY LEFT BLANK ...
Page 70: ...69 PAGE INTENTIONALLY LEFT BLANK ...