A. Technical appendix
A−7
Festo P.BE−CPX−FB23−EN en 0308NH
Diagnostic memory parameters
Function no.
Default setting
Entries remanent with Power On
Contents of the diagnostic memory will be
deleted after new Power On.
3480
Active
Run/Stop filter 1
Defines the saved faults.
3480
Save the last 40 faults
(overwrite old entries).
Run/Stop filter 2
Defines when the recording of faults is to be
started or stopped.
3484
Run/Stop filter 2 inactive
Fault end filter
Defines whether current faults are to be
recorded or not.
3484
Record current faults
(fault end) (filter inactive)
Fault number filter
Suppresses or records exclusively certain faults.
3484
Fault number filter inactive
Module/channel filter
Exclusive recording of faults of a module or
channel (see function nos. 3485...3486).
3484
Module/channel filter
inactive
Module number (MN)
Module number for diagnostic memory filter
3485
Module number 0
Channel number (CN)
Channel number for diagnostic memory filter
3486
Channel number 0
Fault number (FN)
Fault number for diagnostic memory filter
3487
Fault number 0
Tab.A/6:
Diagnostic memory parameters
Summary of Contents for CPX-FB23
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE CPX FB23 EN en 0308NH...
Page 15: ...Installation 1 1 Festo P BE CPX FB23 EN en 0308NH Chapter 1...
Page 45: ...Commissioning 2 1 Festo P BE CPX FB23 EN en 0308NH Chapter 2...
Page 86: ...2 Commissioning 2 42 Festo P BE CPX FB23 EN en 0308NH...
Page 87: ...Diagnosis and error treatment 3 1 Festo P BE CPX FB23 EN en 0308NH Chapter 3...
Page 104: ...3 Diagnosis and error treatment 3 18 Festo P BE CPX FB23 EN en 0308NH...
Page 105: ...Technical appendix A 1 Festo P BE CPX FB23 EN en 0308NH Appendix A...
Page 117: ...Index B 1 Festo P BE CPX FB23 EN en 0308NH Appendix B...
Page 118: ...B Index B 2 Festo P BE CPX FB23 EN en 0308NH Contents B Index B 1 B 1 Index B 3...