1. Installation
1−9
Festo P.BE−CPX−FB23−EN en 0308NH
Setting the operating mode
1
You can set the operating mode of the CPX terminal with
switch element 1 of the 2−element DIL switch 1:
Operating mode
Setting DIL switch 1.1
Operating mode Remote I/O
All functions of the CPX terminal are
controlled directly by the higher−
order PLC/IPC. An FEC integrated in
the CPX terminal functions as a
passive function module without
controller.
1.1: OFF
(factory setting)
Reserved for future extensions:
Operating mode Remote Controller
An FEC integrated in the CPX ter
minal takes over control of the I/Os.
Thi soperating mode is useful if an
FEC is integrated in the CPX ter
minal.
1.1: ON
Tab.1/1:
Operating mode
Please note
The setting of the operating mode with the DIL switch has
priority over all other settings.