1. Installation
1−12
Festo P.BE−CPX−FB23−EN en 0308NH
Limitations in connecting
the modules
The following conditions apply for the number of slave
modules per network:
Max. 64 slave modules per network.
The following condition must be fulfilled:
1 x a + 2 x b + 3 x c + 4 x d
Ţ
64
with: a: Number of slaves with 1 station
b: Number of slaves with 2 stations
c: Number of slaves with 3 stations
d: Number of slaves with 4 stations
The following condition must be fulfilled:
16 x A + 54 x B + 88 x C
Ţ
2304
with: A: Number of remote I/O stations
Ţ
64
B: Number of remote device stations
Ţ
42
1)
C: Number of local / intelligent device stations
Ţ
26
1)
CPX−FB23
Recommendation:
Assign the addresses in ascending order. Adapt the
addresses to suit the machine structure of your system.
Summary of Contents for CPX-FB23
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE CPX FB23 EN en 0308NH...
Page 15: ...Installation 1 1 Festo P BE CPX FB23 EN en 0308NH Chapter 1...
Page 45: ...Commissioning 2 1 Festo P BE CPX FB23 EN en 0308NH Chapter 2...
Page 86: ...2 Commissioning 2 42 Festo P BE CPX FB23 EN en 0308NH...
Page 87: ...Diagnosis and error treatment 3 1 Festo P BE CPX FB23 EN en 0308NH Chapter 3...
Page 104: ...3 Diagnosis and error treatment 3 18 Festo P BE CPX FB23 EN en 0308NH...
Page 105: ...Technical appendix A 1 Festo P BE CPX FB23 EN en 0308NH Appendix A...
Page 117: ...Index B 1 Festo P BE CPX FB23 EN en 0308NH Appendix B...
Page 118: ...B Index B 2 Festo P BE CPX FB23 EN en 0308NH Contents B Index B 1 B 1 Index B 3...