3. Diagnosis and error treatment
3−17
Festo P.BE−CPX−FB23−EN en 0308NH
3.5
Fault treatment
The reaction of the CPX terminal to the following faults de
pends on the HOLD/CLEAR setting undertaken with the DIL
switches:
communication interruption
communication time−out.
Depending on the setting, the outputs (valves and electric
outputs) will be switched off (factory setting) or retain their
status (see section 2.3.1).
Warning
·
Make sure that valves and outputs are put into a safe
state if the faults named occur.
An incorrect status of the valves and outputs can lead to
dangerous situations.
Please note
Please note the following if the outputs are reset after
master stop, field bus interruption or fault:
single−solenoid valves move to the basic position
double−solenoid valves remain in the current position
mid−position valves move to the mid−position (depend
ing on valve type: pressurized, exhausted or blocked).
Summary of Contents for CPX-FB23
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE CPX FB23 EN en 0308NH...
Page 15: ...Installation 1 1 Festo P BE CPX FB23 EN en 0308NH Chapter 1...
Page 45: ...Commissioning 2 1 Festo P BE CPX FB23 EN en 0308NH Chapter 2...
Page 86: ...2 Commissioning 2 42 Festo P BE CPX FB23 EN en 0308NH...
Page 87: ...Diagnosis and error treatment 3 1 Festo P BE CPX FB23 EN en 0308NH Chapter 3...
Page 104: ...3 Diagnosis and error treatment 3 18 Festo P BE CPX FB23 EN en 0308NH...
Page 105: ...Technical appendix A 1 Festo P BE CPX FB23 EN en 0308NH Appendix A...
Page 117: ...Index B 1 Festo P BE CPX FB23 EN en 0308NH Appendix B...
Page 118: ...B Index B 2 Festo P BE CPX FB23 EN en 0308NH Contents B Index B 1 B 1 Index B 3...