1. Installation
1−27
Festo P.BE−CPX−FB23−EN en 0308NH
Please note
In order to comply with protection class IP65/IP67:
·
Fit the DIL switch cover.
·
Seal the service interface with the protective cap
supplied.
·
Use the Festo sub−D plug.
Note that only the Festo sub−D plug guarantees
compliance with protection class IP65/IP67.
Connecting with sub−D plugs of other manufacturers
Connecting with sub−D plugs of other manufacturers:
·
Replace the two flat screws with bolts
(type UNC4−40/M3x6).
·
Connect the cable screening/shield to the plug housing.
Summary of Contents for CPX-FB23
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE CPX FB23 EN en 0308NH...
Page 15: ...Installation 1 1 Festo P BE CPX FB23 EN en 0308NH Chapter 1...
Page 45: ...Commissioning 2 1 Festo P BE CPX FB23 EN en 0308NH Chapter 2...
Page 86: ...2 Commissioning 2 42 Festo P BE CPX FB23 EN en 0308NH...
Page 87: ...Diagnosis and error treatment 3 1 Festo P BE CPX FB23 EN en 0308NH Chapter 3...
Page 104: ...3 Diagnosis and error treatment 3 18 Festo P BE CPX FB23 EN en 0308NH...
Page 105: ...Technical appendix A 1 Festo P BE CPX FB23 EN en 0308NH Appendix A...
Page 117: ...Index B 1 Festo P BE CPX FB23 EN en 0308NH Appendix B...
Page 118: ...B Index B 2 Festo P BE CPX FB23 EN en 0308NH Contents B Index B 1 B 1 Index B 3...