3. Electrical installation
3−14
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
3.4.2
Power supply concept, formation of power zones
The modular power supply concept of the CPX terminal allows
power zones to be formed.
Observe the following:
The internal electronics of the VPWP and the digital posi
tion measuring system and, if present, the sensor inter
face are supplied with power by the electronics/sensors
operating voltage supply (U
EL/SEN
).
The VPWP load supply and the VPWP outputs are sup
plied with power by the valve load supply (U
VAL
).
The CMAX internally connects the contact rails 0 V
EL/SEN
to 0 V
VAL
of the CPX terminal.
This means that the operating power supply for the
electronics/sensors (U
EL/SEN
) of the CPX terminal and
the CMAX load supply for the valves (U
VAL
) are no
longer electrically isolated.
Complete electrical isolation (all poles) of the valve
supply of the VPWP is therefore
not
possible, even in
conjunction with a CPX valve supply of type CPX−EV−V.
Note
Damage to components and operative malfunctions!
·
The CMAX must be supplied via the same potential
(common power supply unit) as the operating power
supply for the electronics/sensors (U
EL/SEN
) of the
CPX terminal (see also Fig.3/3).
The CMAX always connects the 0 V supply for the elec
tronics with the 0 V supply for the valves. This must be
observed when a CPX−GE−EV−V interlinking block is located
to the left of the CMAX because this can remove any inten
tional electrical isolation.
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...