4. Commissioning
4−9
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Delivery status
(first switch−on or after data reset)
The connected components (valve and displacement en
coder/sensor interface) are automatically looked for at
the axis interface. The contained information is read out.
The recognised components are
not
automatically ac
cepted as the target state.
The controller cannot be activated until the axis data is
completely parameterised
1)
. Actual values are then not
updated.
1)
The target configuration (of the mechanics data) must
have been compared with the actual configuration.
Normal start−up
The connected components (valve and displacement en
coder/sensor interface) are automatically looked for at
the axis interface. The contained information is read out.
The found actual configuration is compared with the
target configuration. If there is a deviation, this leads to
an error and the controller is not activated.
This error can only be acknowledged after comparing the
target and actual configurations.
Recognisable parameters
The CMAX automatically acquires all parameter values
which are stored in the drive, sensor (displacement encoder)
or valve. The FCT plug−in can read these values out of the
CMAX. They do not have to be entered in the FCT project.
The acquired data cannot be overwritten.
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...