3. Electrical installation
3−4
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Earthing the drives/displacement encoders...
Depending on the drive or displacement encoder used, these
must be earthed. See Tab.3/1.
Drive
Description
Earthing instructions
DGCI
Linear drive with permanently
integrated position measuring
system.
·
Make a low−impedance connection (earthing
strap) between the flat pin of the position
measuring system and the earth potential!
Flat pin (DIN 46246−2, width: 4.8 mm)
DGP(L)
Linear drive with external position
measuring system MLO−POT−...−TLF.
·
Mount the position measuring system so that it
is electrically isolated.
1)
DNCI
Standard cylinder with integrated
position measuring system.
·
Make a low−impedance connection (short
cable with large cross section) between the
earth terminal on the cylinder and the earth
potential.
1)
A self−tapping screw for mounting an earth strap
is supplied with the displacement encoder.
DNC
Standard cylinder with external
position measuring system
MLO−POT−...−LWG.
·
Make a low−impedance connection (earthing
strap supplied) between the flat pin of the
position measuring system and the earth
potential!
DNCM
Standard cylinder with external
position measuring system already
mounted on delivery.
No earthing is required.
DSMI
Semi−rotary drive with integrated
position measuring system.
·
Make a low−impedance connection (earthing
strap) between the earth terminal of the DSMI
and the earth potential.
1)
Alternatively: Mount the drive on an earthed machine frame.
Tab.3/1: Instructions for earthing the drive and position measuring systems
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...