5. Diagnostics and error handling
5−5
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Acknowledging
malfunctions
Reported malfunctions must be acknowledged with
CCON.RESET. It might be necessary to remedy the cause of
the malfunction.
1. Positive edge on CCON.RESET.
2. Wait 3 s (depending on the malfunction, CMAX requires a
maximum of 3 seconds, e.g. for initialising the axis).
3. Check whether the malfunction has been remedied:
if SCON.FAULT = 0: ok
if SCON.FAULT = 1:
Check the malfunction number and eliminate any
cause. See section 5.2.4.
Fundamentally, CMAX always attempts to acknowledge the
currently pending malfunctions. If there are several malfunc
tions active at the same time, the behaviour is directed to
ward the most serious malfunction.
If there are several malfunctions registered and one malfunc
tion can be cleared by resetting, but the others cannot, the
remaining malfunctions are displayed after the reset.
Warnings
Events and statuses which can potentially impair operation
are signalled as a warning. A list of warning messages can be
found in section 5.2.4.
Warning reaction
In the case of warnings, CMAX does not have the Malfunc
tion" status, but continues to have Ready" status.
Warnings are reported with SCON.WARN = 1. There is no
effect on the sequence control or the axis.
Acknowledging warnings
SCON.WARN is set = 0, depending on the warning:
with the positive edge at CCON.START or CCON.RESET
(as far as the cause has been remedied).
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...