5. Diagnostics and error handling
5−28
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Malfunction group 8 Displacement encoder error
CPX error group 108
(CPX−MMI: [Encoder error])
Continued
No.
Message
Cause/description
Error handling
Type
1)
84
Reference position of dis
placement encoder was
lost
Although the controller
has set the Referenced"
status, the displacement
encoder/sensor interface
signalled Not refer
enced".
·
Reference again.
Error level: F2
Reset: N
85
Operating voltage of
measuring system /
sensor interface is out of
specified tolerance range
(undervoltage)
The operating voltage of
the displacement encoder
is too low.
·
Check the power
supply.
·
Check the cables on
the axis string.
Error level: F2
Reset: F
87
Defective measuring sys
tem cable or measuring
system in the electrical
end−position (potentio
meter only)
Defective displacement
encoder cable.
·
Check the power
supply.
·
Check the cables on
the axis string.
·
It might be necessary
to switch it off and on
again.
·
Exchange the sensor
or sensor interface,
if necessary.
Error level: F2
Reset: N
Displacement encoder in
the electrical end position
(potentiometer only)
·
Move the displace
ment encoder (poten
tiometer) away from
the end position.
1)
For the error level and reset type, see section 5.2.3.
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...