2. Fitting and pneumatic installation
2−27
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Tubing aid for DGCI and DSMI−...−B
When ordering the DGCI with fittings standard (no modular
system feature) or modular system feature QD" or QR", as
well as for DSMI−...−B:
The fittings on the valve and drive have colour−coded releas
ing rings.
·
Connect the fittings with the respective blue and black
releasing rings.
Note
Check the tubing connection with the movement test.
Silencer
The VPWP is available with an integrated flat plate silencer.
When using the VPWP without an integrated flat plate si
lencer:
·
Install silencers with a large nominal flow rate, e.g. UC−
M5, U−1/8, U−1/4 or U−3/8 (depending on valve type)
·
Conduct the collected exhaust air into a small air reservoir
and exhaust this with a large silencer. Make sure that
the fittings and tubing provide sufficient flow (shortest
possible tube length).
A correct layout can reduce the exhaust noise.
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...