5. Diagnostics and error handling
5−32
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
5.3.3
LEDs on the VPWP
Power VPWP logic supply
LED (green)
Sequence
Status
LED
illuminated
ON
OFF
24 V logic supply is present.
LED is off
ON
OFF
VPWP logic supply is not available.
CMAX error: E60
Error VPWP error
LED (red)
Sequence
Status
LED is off
ON
OFF
No error.
LED flashes
ON
OFF
Warning:
Switch−off temperature almost reached
Logic supply lies below 17 V
CMAX error/warning: W68 or E65
LED
illuminated
ON
OFF
Error
1)
CMAX error: E61, E62, E63, E66 or E67
1)
For a message about CMAX error, see section 5.2.4, malfunction group 6.
PL VPWP load supply
LED (yellow)
Sequence
Status
LED
illuminated
ON
OFF
24 V VPWP load supply is present
LED is off
ON
OFF
VPWP load supply is not present
or there is an error.
CMAX error: E64
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...