5. Diagnostics and error handling
5−16
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Malfunction group 3 Regulation error
CPX error group 103
(CPX−MMI: [Control error])
Continued
No.
Message
Cause/description
Error handling
Type
1)
33
Target position outside
software or hardware
endpositions
Target position lies out
side of the set software
end positions.
·
Check target position,
software end posi
tions and project zero
point and correct.
Error
level: F1 (W)
Reset: R
Target position lies out
side of the reachable
hardware end positions.
·
Check target position
and project zero point
and correct.
34
Set−point of tracking
mode outside limits
Target position lies out
side of the set software
end positions.
·
Check setpoint posi
tion, software end
positions and project
zero point and cor
rect.
Error
level: W (F1)
Reset: R
Setpoint position lies
outside of the reachable
hardware end positions.
·
Check setpoint posi
tion and project zero
point and correct.
35
Pass the software end
position
2)
The drive was pushed
out of the valid range by
an external force.
·
If possible, prevent
external force.
Error
level: W (F1)
Reset: R
Controllers which are
not optimally set can
lead to considerable
overshooting.
·
Optimise the
controller, check
parameterisation,
carry out identifica
tion again.
1)
For the error level and reset type, see section 5.2.3.
2)
The actual position exceeded a software end position during active position control.
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...