3. Electrical installation
3−10
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
CASM−S−D3−R7
Sensor interface for digital, incremental displacement encoders
with M12 displacement encoder connection (socket, 8 pin).
Pin
Allocation
S2
1
+ Ub sensor (5 V)
7
1
6
2
0 V
1
6
3
Sine signal +
5
8
4
Sine signal
4
3
2
5
Cosine signal
3
6
Cosine signal +
7
Screen
8
n.c. (not connected)
Housing
Earth terminal (FE)
The cable screening is connected to the earth terminal of the sensor
interface.
Tab.3/7:
Pin allocation of connection S2 for the CASM−S−D3−R7
CASM−S−D2−R3
Sensor interface for analogue, absolute displacement encoders
(potentiometer), with M12 displacement encoder connection
(socket, 5 pin).
Pin
Allocation
S2
1
Displacement encoder housing
3
4
2
n.c. (not connected)
2
1
3
Analogue GND (AGND)
2
1
5
4
Reference voltage 5 V (REF 5V)
5
Analogue input 0 ... 5 V (INPUT)
Housing
Earth terminal (FE)
The cable screening is connected to the earth terminal of the sensor
interface.
Tab.3/8:
Pin assignment of connection S2 for the
CASM−S−D2−R3
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...