5. Diagnostics and error handling
5−36
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
5.4.2
Status display
Possible status information
No.
Status display
Additional
Information
Description
Example
1
." flashing
An
Initialisation of components at the axis interface n
n
nn
After initialising components at the axis interface,
the firmware version is displayed for about 1 s
(e.g. V 1.00).
2
C
nn
Parameterisation phase, with current status nn
3
0
nn
Initialisation is successfully completed. There is no
enable. Current operating mode status display: nn
4
1
nn
Ready for operation, current operating mode in
status display: nn
5
2
nn
Record select operating mode, last or current
positioning record nn
About 1:
Point flashes during the entire initialisation phase.
About 2:
Parameterisation phase, status in
additional information:
00: Wait for system of units
01: Wait for drive type
02: Wait for axis data
03: Wait for movement test
About 3 and 4:
Display of the operating mode in
additional information:
02: Record select
03: Direct mode
04: Commissioning
0P: Parametrising
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...