5. Diagnostics and error handling
5−13
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Malfunction group 2 Execution error
CPX error group 102
(CPX−MMI: [Record error])
Continued
No.
Message
Cause/description
Error handling
Type
1)
27
Switching condition can
not be reached during
movement
Switching position does
not lie between the start
position (last setpoint/
actual value at the time
of the switch) and the
new setpoint position or
both positions are the
same.
·
Check the switching
condition and correct,
if necessary. Check the
program sequence in
the PLC. After a stop or
an error, the previous
position must be ap
proached again.
Error
level: F1 (W)
Reset: R
The switching force is
not between the starting
force (last setpoint/
actual value at time of
switching) and the new
force setpoint.
28
Switching condition has
not been reached
Switching has not been
carried out yet MC was
reached before the
switching condition was
met.
·
Check the switching
condition. Parameterise
as warning, if
necessary.
Error
level: F1 (W)
Reset: R
1)
For the error level and reset type, see section 5.2.3.
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...