5. Diagnostics and error handling
5−22
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
Malfunction group 5 System error B
CPX error group 105
(CPX−MMI: [System error B])
No.
Message
Cause/description
Error handling
Type
1)
50
Operating pressure is too
low
2)
Pressure in both cylinder
chambers is <1.5bar.
·
Check the pressure
supply.
·
Wait until the cylinder
chambers are suffi
ciently filled (possibly
via leakage through
valve).
·
Configure as warning.
Error
level: F2 (W)
Reset: F
51
Controller load voltage
outside tolerance range
(undervoltage)
Load voltage < 20 V for en
abled controller or over
load on axis string.
·
Check the valve load
supply (U
VAL
).
Error level: F2
Reset: F
52
Controller operating volt
age outside tolerance
range (undervoltage)
Operating voltage <18V or
overload on axis string.
·
Check the operating
voltage supply for
electronics/sensors
(U
EL/SEN
).
Error level: F2
Reset: F
53
Controller: Overload load
supply
Short circuit in the cables
of the axis string (between
the controller and valve or
valve and sensor inter
face).
·
Check the cables and
modules in the axis
string (e.g. for a cable
breakage), replace if
necessary.
Error level: F2
Reset: F
Defect in the CMAX con
troller.
·
Check CMAX and ex
change, if necessary.
Defect in the valve.
·
Check the lines and
valves step−by−step
and exchange, if
necessary.
Overload in valve outputs.
·
Check output connec
tions and correct, if
necessary.
1)
For the error level and reset type, see section 5.2.3.
2)
Enable command, but no supply pressure.
Summary of Contents for CPX-CMAX-C1-1
Page 2: ......
Page 22: ...Contents and general safety instructions XX Festo P BE CPX CMAX SYS EN en 0908NH...
Page 23: ...CMAX system overview 1 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 1...
Page 31: ...Fitting and pneumatic installation 2 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 2...
Page 60: ...2 Fitting and pneumatic installation 2 30 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 61: ...Electrical installation 3 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 3...
Page 79: ...Commissioning 4 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 4...
Page 122: ...4 Commissioning 4 44 Festo P BE CPX CMAX SYS EN en 0908NH...
Page 123: ...Diagnostics and error handling 5 1 Festo P BE CPX CMAX SYS EN en 0908NH Chapter 5...
Page 163: ...Technical appendix A 1 Festo P BE CPX CMAX SYS EN en 0908NH Appendix A...
Page 176: ...A Technical appendix A 14 Festo P BE CPX CMAX SYS EN en 0908NH...