9 Levelling system operation
123
9.9.2 Controlling with the 3D TPS
1) Use the auto/manual button to
switch the controller to "manual"
operating mode.
2) Select the
3D TPS
as sensor
as described.
The sensor symbol and the
symbol for "manual" are
shown on the display.
6
3D
3) Move the screed to the
working position for
calibration to zero using
the up/down buttons on
the controller or the
operating device on the
vehicle.
4a) Press the enter
button.
The nominal value has
a black background
and the current actual
value is taken over as
the nominal value.
4b) Keep the enter button
pressed for approx. 2 seconds.
The actual value and the
nominal value initially have a
black background.
The actual value and the
nominal value are set to "0.0".
5) Use the auto/manual
button to switch the
controller to "automatic"
operating mode.
The controller adjusts
the screed to the
values stated by the
3D system, depending
on the screed position.
6) In automatic mode, the
up/down buttons can now
be used to change the
nominal value to enable
corrections to be carried
out.
c m
6
0. 0
0. 0
3D
c m
9. 8
6
9. 8
3D