152
14 Help in the event of malfunctions
General:
Cause: The sensor last used has been exchanged or removed;
Remedy: Select another sensor in the sensor selection or check why
the sensor is no longer available;
OUT
Cause: Positive or negative deviation of the active sensor's measured
value from the permissible measuring range or the power mast has
reached the upper or lower stop of its mechanical adjustment range;
Control outputs: The outputs are locked in automatic mode;
Remedy: Realign the sensor to the reference;
Cause: The active sensor's control variance is greater than the set
control window;
Control outputs: The outputs are locked in automatic mode;
Remedy: Realign the sensor via the reference;
Specifically when working with the laser receiver:
Cause: The laser receiver receives several signals from the laser
transmitter due to reflections in its environment;
Control outputs: The outputs are locked in automatic mode;
Remedy: Cover the laser transmitter apart from the actually required
circular cut-out;
Remove reflective surfaces (motor vehicle glazing, windows, etc.) from
the laser beam's area of influence or cover these surfaces;