160
14 Help in the event of malfunctions
Specifically when working with TPS
(total station)
:
Cause: The total station has lost the prism, thus interrupting the direct
"view" of the prism;
Control outputs: The outputs are locked in automatic mode;
Remedy: The total station automatically starts target tracking again after
measurement was interrupted;
If necessary, the operator has to restart the total station prism search by
hand;
Cause: The total station is searching for the prism;
Control outputs: The outputs are locked in automatic mode;
Remedy: Please be patient for a moment; the prism search can take a
little time;
If necessary, start the total station extended search;
3D
Cause: An unspecified 3D error has occurred;
Control outputs: The outputs are locked in automatic mode;
Remedy: Please comply with the information about the error given on the
total station and system computer displays;
Cause: The total station battery is flat;
Control outputs: The outputs are locked in automatic mode;
Remedy: Replace or recharge the battery;
OUT
Cause: The vehicle is outside the project or surface design;
Control outputs: The outputs are locked in automatic mode;
Remedy: Move back into the project or select the surface design
belonging to the current position;