8 Operation in general
77
8.8.1 Manual control system
Navigate to the crowning in the view menu.
Select manual adjustment using the up/down buttons.
Confirm the selection with the enter button.
ATTENTION!
The crowning is adjusted directly by pressing the up/down
buttons!
If a crowning sensor is present, the currently
measured value is shown.
Special function crowning - actual value reset:
The crowning sensor must always be calibrated when putting
into operation (initial installation or when replacing the
sensor).
Even so, when the screed is under load it is still possible for it
to adjust to a value that deviates somewhat from the
calibration.
The displayed actual value can be adjusted to correct this
offset.
To this end, adjust the actual value to the correct setting,
using the two up/down buttons (2) while holding the input
button (1).
0. 84
If no crowning sensor is available, no current value is
displayed.
Crowning adjustment can still be carried out using the
up/down buttons.
Press function button F1 to return to the crowning selection
window.
Press function button F2 to activate the display with 2 control
circuits.
Here it is possible to show the crowning control and levelling
at the same time.
Press F3 to cancel the process and to return to the main
menu.
- - -