8 Operation in general
83
The other windows in the user menu include:
XX.X
X
Display brightness
The brightness of the display backlighting can be set to ensure that the
display remains clearly legible even in the event of unfavourable light
conditions.
LED arrow brightness
The luminance of the LED arrow can also be individually adapted.
Sensitivity
The "sensitivity" parameter defines how quickly and aggressively the
levelling system reacts to a variance.
The setting range extends from 1 (low sensitivity) to 10 (high
sensitivity).
The numerical values conceal a sensible combination of the "dead
band" and prop band" parameters determined in a long series of tests.
The value tables can be found on the following page.
The sensitivity value must be set separately for distance and slope
sensors, and is subsequently automatically loaded when a sensor is
switched.
If the remote control operates too erratically in automatic mode, the
sensitivity of the corresponding remote control must be reduced. If the
remote control operates too sluggishly in automatic mode, the
sensitivity must be increased accordingly.
In the basic settings, the setting can be changed in such a way that the
concealed "dead band" and "prop band" parameters are shown instead
of the "sensitivity" parameter. These can then be individually adapted
by trained personnel.