9 Levelling system operation
127
9.11.3 Controlling with the 3D slope sensor
1) Use the auto/manual
button to switch the controller
to "manual" operating mode.
2) Select the
3D slope sensor
as described.
The sensor symbol and
the symbol for "manual"
are shown on the display.
6
3D
3) Use the up/down
buttons on the controller
to move the screed to the
nominal value defined by
the 3D system for the
current position,
4) Use the auto/manual
button to switch the controller
to "automatic" operating
mode.
The controller adjusts the
screed to the values
stated by the 3D system,
depending on the screed
position.
When working with the 3D slope sensor, the up/down buttons on the
controller cannot be used to adjust the nominal value!
To make any adjustments to the slope, firstly the digital slope sensor must be
selected as active sensor.