S1C6S3N2 TECHNICAL HARDWARE
EPSON
I-9
CHAPTER 2: POWER SUPPLY AND INITIAL RESET
LCD system power supply
For the LCD system power supply, either "internal" (to
generate internally) or "external" (to supply from outside of
the IC) can be selected. The LCD panel voltage has been
decided depending on the model and selection of the LCD
system power supply.
When "external" is selected by the mask option, the specified
LCD drive voltage terminal is connected to the V
SS
inside the
IC.
Combinations that are marked with an "
×
" cannot be selected.
1/3 Bias
Internal
V
L1
= V
SS
×
×
×
×
V
L1
/ V
L2
3.0 V LCD
3.0 V LCD
3.0 V LCD
3.0 V LCD
S1C6S3N2
S1C6S3A2
S1C6S3L2
S1C6S3B2
External
V
L2
= V
SS
×
4.5 V LCD
×
×
V
L3
= V
SS
3.0 V LCD
3.0 V LCD
×
×
1/2 Bias
Internal
V
L1
= V
SS
×
×
3.0 V LCD
V
L1
/V
L2
×
×
×
S1C6S3N2
S1C6S3A2
S1C6S3L2
External
V
L2
= V
SS
×
×
×
V
L3
= V
SS
3.0 V LCD
3.0 V LCD
×