I-60
EPSON
S1C6S3N2 TECHNICAL HARDWARE
CHAPTER 4: PERIPHERAL CIRCUITS AND OPERATION (LCD Driver)
CSDC:
LCD drive switch
(078H·D3)
The LCD drive mode can be selected with this switch.
When "1" is written :
Dynamic drive (Normal mode)
When "0" is written :
LCD ALL OFF (ALL OFF mode)
Read-out :
Valid
At initial reset, this register is set to LCD ALL OFF.
The LCD segments are lit or turned off depending on this
data.
When "1" is written :
Lit
When "0" is written :
Not lit
Read-out :
Valid for 40H–6FH
Undefined C0H–EFH
By writing data into the segment data memory allocated to
the LCD segment (on the panel), the segment can be lit or
put out.
At initial reset, the contents of the segment data memory are
undefined.
(1) When 40H–6FH is selected for the segment data memory,
the memory data and the display will not match until the
area is initialized (through, for instance, memory clear
processing by the CPU). Initialize the segment data
memory by executing initial processing.
(2) When C0H–EFH is selected for the segment data memory,
that area becomes write-only. Consequently, data cannot
be rewritten by arithmetic operations (such as AND, OR,
ADD, SUB).
Programming notes
Segment data memory
(40H–6FH or C0H–EFH)